Our special unit
from:
01.02.2012
MAXX Special Pressurised lines
Task:
Samples had to be extracted from a pressurised line >1 bar. The extraction point was 2 resp. 10 m above the sampler. A fixed single sample volume at a variable pressure had to be guaranteed. An unpressurised discharge was not possible.
Further information...
|
|
|
Our special unit
from:
01.01.2012
MAXX Special Controldata memory
Task:
For a hydrocyclone test facility the control unit with the respective software should be built according to the customer´s specifications.
Further information...
|
|
|
Our special unit
from:
01.12.2011
MAXX Special measuring-station pH Conductivity Te
Task:
Replacement of an existing measuring station installed in a cheese dairy by a combined unit with measuring cabinet and self-emptying sampler. The measuring pot used in the old station had to be replaced as the eccentric screw pump used up to that time caused very high maintenance costs. Thus the measuring units should be supplied with sample liquid by means of a vacuum sampling system with measuring pot installed after the metering vessel.
Further information...
|
|
|
Our special unit
from:
01.11.2011
MAXX Special Special-containers 4x60l
Task:
The sampler had to have 4 x 60 l containers. There had to be two telescopic drawers, each with two containers. To empty the containers, they had to have a discharge valve.
Further information...
|
|
|
Our special unit
from:
01.10.2011
MAXX Special Special-containers composite-sample event wastewater
Task:
Standard SP I-Var had to be equipped with a distributor with 6 bottles for a composite sample as well as a composite container for event samples and vice versa (option).
Further information...
|
|
|
Our special unit
from:
01.09.2011
MAXX Special Special-containers 6x25L
Task:
Standard device with 6 x 25 l containers.
Further information...
|
|
|
Our special unit
from:
01.08.2011
MAXX Special XY distributor external start
Task:
The sample distributor had to be adapted to the customer´s bottles. The bottles had to be placed on a telescopic drawer with rolls. A direct filling into the sample bottles was required. Sampler housing material: 1.4571. Each bottle tray had to be equipped with three bottles. A program start by means of an external pushbutton had to be possible.
Further information...
|
|
|
Our special unit
from:
01.07.2011
MAXX Special XY distributor 28-bottles
Task:
The sampler had to be used as monitoring unit. There had to be 28 bottles for programmable hourly composite samples and 7 bottles for a daily composite sample. Additional bottles had to be available for eventproportional samples. The sample extraction had to be effected with one control unit, one distributor and parallel programs.
Further information...
|
|
|
Our special unit
from:
01.06.2011
MAXX Special XY distributor open-frame
Task:
A device similar to the fixed-site samplers in stainless steel housing, however, without housing, had to be supplied. Furthermore it had to be possible to disassemble the sampler easily as it had to pass very narrow stairs.
Further information...
|
|
|
Our special unit
from:
01.05.2011
MAXX Special XY distributor
Task:
A portable sampler made of inert material had to be equipped with a housing (without cooling) and a distributor for 12x1l and 6x2 l bottles.
Further information...
|
|
|
Our special unit
from:
01.04.2011
MAXX Special Sewer ex-proof
Task:
The device should be used in the sewer. To collect the sample from the sampler, the sampler did not have to be taken out of the sewer. Thus the sample had to be transported upwards pneumatically.
Further information...
|
|
|
Our special unit
from:
01.03.2011
MAXX Special self-emptying
Task:
A self-emptying sampler like SPI-A 2x10 l should be equipped with 4 x 5 l bottles. The bottles should be emptied and rinsed automatically. The program flow had to be in such a way that always 3 filled bottles are available. If needed, it has to be possible to drain the sample manually.
Further information...
|
|
|
Our special unit
from:
01.02.2011
MAXX Special self-emptying sampler for measuring station
Task:
The customer asked for a self-emptying sampler which should be installed
in a measuring container for canal monitoring. A fixed allocation of the
bottles, a simple operation and samples that cannot be confused when
collected have been the main requirements.
The component parts had to guarantee a maximum operation reliability.
Further information...
|
|
|
Our special unit
from:
01.12.2010
MAXX Special sampler for Volatiles VOC
Task:
A „careful“ sample extraction from a pump line with river water had to be
effected. Thus it has been very important to avoid vacuum and turbulences and that
the sample was led very gently into the bottle.
Further information...
|
|
|
Our special unit
from:
01.11.2010
MAXX project with Fraunhofer IGB in Brasil, MAXX Special Control unit for small sewage plants with data logger GSM Remote communication
Task:
In the framework of a research project in Brazil, a special software with PLC control for local sewage plants up to 2000 inhabitants had to be
developed in cooperation with the Fraunhofer Institute according to their specifications. The sewage plant has to be able to control diverse stages
of expansion. In the maximum stage of expansion the plant is also able to eliminate phosphate and nitrate from the waste water.
Further information...
|
|
|
Our special unit
from:
01.10.2010
MAXX Special Control with data logger, GSM Remote communication and customized Software
Task:
The customer wanted to store the flow signal of three different inlet line measurements (sewage plant inlet) and to fetch them via GSM modem.
Furthermore the unit had to function without mains power. MAXX provided the control unit with GSM modem and the customerspecific software for this project.
Further information...
|
|
|
Our special unit
from:
01.09.2010
MAXX Special sampler with fridge for frozen samples
Task:
Samples shall be extracted from a pressurised ring line, filled into bottles
and shall be frozen.
Further information...
|
|
|
Our special unit
from:
01.08.2010
MAXX Special sampler with parallel 6-channel sampling
Task:
The customer wanted to take samples from 6 canals in parallel. The samples should be extracted in the flow-dependent sampling mode and be
filled into only one composite container.
Further information...
|
|
|
Our special unit
from:
01.07.2010
MAXX Special Control with data logger, web interface, sampler with pneumatic system
Task:
Customer wanted to have a device which is exactly meeting his requirements regarding the configuration, used components and software and which can be administered in a network by means of a web interface.
Further information...
|
|
|
Our special unit
from:
01.06.2010
MAXX Special Special containers with 4 x 60 L on telescopic drawers
Task:
The sampler had to have 4 x 60 l containers. There had to be two telescopic drawers, each with two containers. To empty the containers, they had to have a discharge valve. The samples should be extracted from two different sewers by means of separate sampling systems and a parallel dosing into the containers.
Further information...
|
|
|
Our special unit
from:
01.05.2010
MAXX Special Measuring station, sampler with flow-through-system, double pump, transducers for online measuring
Task:
A double measuring station had to be equipped with a self-emptying
sampler with flow-through sampling system in one part of the sampler
housing and a measuring rack with measuring pot in the other part of the
housing. Beside the measuring station had to be installed another housing for a
pump and a distribution box.
Further information...
|
|
|
Our special unit
from:
01.04.2010
MAXX Special automatic sampler with XY distributor 36 x 2,9 L
Task:
Devices for river monitoring with 36 x 2,9 l bottles.With additional
function keys for special functions. Data fetch and parameterization is
effected via remote function with modem (analogue, ISDN and GSM).
Further information...
|
|
|
Our special unit
from:
01.03.2010
MAXX Special thick-insulation 60mm, peristaltic pump sampler with high accurate Volume measuring system
Task:
The sampler should be built according to the customer´s specifications
Especially the housing with thicker insulation and with Peristaltic pump.
Further information...
|
|
|
Our special unit
from:
01.02.2010
MAXX Special sampler for pressurised lines in tanneries with very aggressive wastewater
Task:
The device is used in aggressive ambient conditions and with aggressive fluids with a high solids content (tanneries). The sample is extracted from a pressurised line. The sampler has to be self-emptying with 2 x 10 l bottles.
Further information...
|
|